It is known that the temperature of combustion flames should be less than 3,272 F to prevent NOx generation. Generally, combustion flames will have some high temperature areas generating NOx. |
 |
Miura engineers calculated the temperature distribution in the combustion and the heat exchanging areas. From theoretical analysis and rigorous testing, the designed temperature distribution is homogeneously less than 3,272 F. |
 |
The burner surface is made as large as possible and the furnace volume as small as possible to optimize the combustion process. As a result, with no efficiency loss at 3% O2 and 85% efficiency, the LX has NOx emissions of less than 20 ppm (lower NOx available for California). |
|
|